Candy TRIO 9503 X User Manual Page 5

  • Download
  • Add to my manuals
  • Print
  • Page
    / 80
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 4
ELECTRICAL CONNECTION
"The installation must conform to the standard directives".
The manufacturer declines all responsibility for any damage that
may be caused by unsuitable or unreasonable use.
Warning :
• Always check before any electrical operation, the supply tension
shown on the electricity meter, the adjustment of the circuit-
breaker, the continuity of the connection to earth to the installation
and that the fuse is suitable.
The electrical connection to the installation should be made via
a socket with a plug with earth, or via an omni pole cut-out
switch .
If the appliance has a socket outlet, it must be installed so that
the socket outlet is accessible.
The manufacturer cannot be held responsible for any accidents
resulting from the use of an appliance which is not connected
to earth, or with a faulty earth connection continuity.
• Any queries regarding the power supply cord should be referred
to After Sales Service or a qualified technician.
Warning! This appliance must be earthed. In the absence of
adequate earthing you will notice that when touching the
metal parts of your appliance an electrical dispersion can be
felt due to the presence of a radio interference suppressor.
• TRIO 9501
A power cord is supplied with the Trio which allows it to be
connected only to a power supply of 220-230 V between
phases, or between phase and neutral. Connect to a 10/16
Amp socket.
• TRIO 9503
A power cord is not supplied with this Trio, but it is equipped with
a terminal block that enables you to choose the correct connection
for the particular power supply.
The terminal block is located at the back of the Trio.
To open the terminal block :
. Locate the two tabs on the sides,
. place the screwdriver blade on the front of the tab, insert it (1)
and press down (2)
. Lift the cover off.
Terminal block
x 3 bars shunts
To connect :
. unscrew the cable grip,
. pass the cable through the cable grip,
. strip the insulation off the end of the each wire and connect them
to the according to the numbers shown in the table as well as
the "bars shunts".
4 GB
INSTALLATION
Example of connection in monophase
1- Put in the
bars shunts
2- Put in
the wires
3- Pass the cable
through the cable grip
Caution: incorrect tightening can cause dangerous heating
risks for the power supply cable.
H05VV-F
3 G 2,5 mm
2
Monophase
220-230V~
25 AFUSE
CABLE
TYPE-AERA
2 Phase
Shunt 1-2
Shunt 2-3
5 Neutral
Shunt 4-5
T Earth
CONNEC-
TION TO
THE
TERMINAL
BLOCK
To Shunt:
make a
bridge with a
shunt bar
H05RR-F,
H05VV-F or,
4 G 2,5 mm
2
H05VV-F or,
H05RR-F
5 G 1,5 mm
2
Three phases
220-230V3~
Three phases
380-415V3N~
25 A 16 A
1 Phase
Shunt 1-2
3 Phase
Shunt 3-4
5 Phase
T Earth
1 Phase
2 Phase
3 Phase
5 Neutral
Shunt 4-5
T Earth
L2
L3
When the connection operation to the appliance terminals is
finished, tighten the cable clamp and close the cover.
Page view 4
1 2 3 4 5 6 7 8 9 10 ... 79 80

Comments to this Manuals

No comments