blinking, the anti-grease filters must be cleaned and the charcoal filters replaced (120 hours of operation). Obviously, if the
hood is not a filtering model and does not have a charcoal filter , clean the anti-grease filters both when the central segment
goes on and when it starts blinking. The filter alarm can be seen when the motor is off and for about 30 seconds. To reset
the hour counter, keep the button pressed for 2 seconds while the alarm can be seen.
Commands shown in Fig. 17: Button A = light button. Button B = first speed motor ON/OFF button. Button C = second
speed button. Button D = third speed button. E = motor on light.
Commands shown in Fig. 18: Button A: turns the lights on/off; every 30 hours of operation the corresponding pilot lamp
(S) comes on to indicate that the anti-grease filters must be cleaned; every 120 hours of operation the corresponding pilot
lamp (S) flashes to indicate that the anti-grease filters must be cleaned and the charcoal filter replaced. To restart the hour
counter (RESET), hold the button A pressed down for about 1” (while the pilot lamp S is on). Button B: drives the motor
in first speed (the corresponding pilot lamp comes on); when holding it down for about 1”, the motor cuts out. Button C:
drives the motor in second speed (the corresponding pilot lamp comes on); when pressing the button a second time (while
the pilot lamp is on) , the TIMER is activated and thus the motor stops after 5’ (the pilot lamp flashes). Button D: drives
the motor in third speed (the corresponding pilot lamp comes on); when pressing the button a second time (while the pilot
lamp is on) , the TIMER is activated and thus the motor stops after 5’ (the pilot lamp flashes). Button E: drives the motor
in fourth speed (the corresponding pilot lamp comes on); when pressing the button a second time (while the pilot lamp is
on) , the TIMER is activated and thus the motor stops after 5’ (the pilot lamp flashes).
Pay special attention to the anti-grease filters:
if the model purchased has the commands shown in Figure 16: the anti-
grease filters must be cleaned approximately once every 30 hours of operation (when the central segment on the display
goes on or starts blinking). To remove the filters: press inward on the clamps at the handles and pull the filter downward.
Wash out the filter by hand or in the dishwasher using a neutral soap. Once the cleaned filters are reinstalled, keep button
R (Reset) pressed for two seconds to reset the counter. For further information, see the Commands in Fig. 16 in the
paragraph entitled “Operation”.
If the model purchased has the commands shown in Figure 17: the grease filter must be
replaced periodically: exactly how often depends on use (at least once every other month). To remove the filter: push inward
on the clamp at the handle and pull the filter downward. Wash out the filter by hand or in the dishwasher using a neutral
soap.
If the model purchased has the commands shown in Figure 18: the anti-grease filters must be cleaned approximately
once every 30 hours of operation (when the light button lamp comes on) - Fig. 18S). To remove the filters: press inward
on the clamps at the handles and pull the filter downward. Wash out the filter by hand or in the dishwasher using a neutral
soap. Once the cleaned filters are reinstalled, to reset the counter hold the light button pressed down for about 1” (Fig.18A)
while the corresponding pilot lamp (S) is on. For further information, see the Commands in Fig. 18 in the paragraph entitled
“Operation”.
Replacing the charcoal filters: If the unit is a filtering hood, the charcoal filters must be replaced: to remove them press
inward on the clamp (Fig. 15) and rotate the filter downward until the 2 tabs can be removed from the housing.
If the model purchased has the commands shown in Figure 16, the charcoal filters must be replaced whenever the central
segment of the display starts blinking (i.e. every 120 hours of operation). If the model purchased has the commands shown
in Figure 17, the charcoal filters must be replaced according to use: on average once every 6 months. If the model
purchased has the commands shown in Figure 18, the charcoal filters must be replaced each time the light button (Fig.18S)
lamp flashes (i.e. every 120 hours of operation).
Lighting: Depending on the model purchased, see Fig.19 or Fig. 20.
Fig. 19: to remove the halogen lamps, turn the locknut counter-clockwise. Replace with the same type of lamp.
Fig. 20: if your appliance has the same kind of lights as in the figure 20, to replace the incandescent light bulbs remove
the anti-grease filters and remove it; replace with light bulbs of the same type.
DEUTSCH
BESCHREIBUNG
Das Gerät kann in Filterversion, in Aspirationsversion und in der Version mit externem Motor geliefert werden.
In der
Filterversion (Abb. 1) werden die durch das Gerät geleitete Luft und der Dampf durch Kohlefilter gereinigt und dann über
die seitlichen Lüftungsgitter der Haube wieder in Zirkulation gebracht. ACHTUNG! Beim Einsatz der Filterversion müssen
die Kohlefilter zusammen mit einem Luftablenker eingesetzt werden, der in den oberen Rohrabschnitt montiert wird und
die Rezirkulation der Luft und Ableitung in die Umgebung ermöglicht (Abb. 1A).
In der Aspirationsversion (Abb. 2)
werden die Dämpfe und Küchengerüche direkt über eine Evakuationsöfffnung in der Wand oder Decke nach außen
a/jointfilesconvert/1335466/bgezogen. Daher sind keine Kohlefilter notwendig. In der Version mit externem Motor (Abb. 3) ist das Gerät mit einer
Aspirationszentrale zu verbinden, die getrennt arbeitet und das Gerät als Verbindungsbasis für die abzuleitende Luft
benutzt. Bitte verwenden Sie nur eine der im Originalkatalog vorgeschlagenen Zentralen.
INSTALLATION
Vor den Montageoperationen muß/müssen zur leichteren Handhabung des Geräts der/die Antifettfilter entfernt werden:
Den Festhalter in der Nähe des Griffs nach innen drücken und den Filter nach unten ziehen (Abb. 4).
Befestigung an der Wand (Abb. 5): Bohren Sie mit der mitgelieferten Bohrschablone die Löcher an den jeweiligen Stellen
an der Wand. Wie bereits im Kapitel “Montage und Gebrauchsanweisung” beschrieben ist darauf zu achten, daß der
Abstand zwischen dem unteren Rand der Haube und der Kochfläche mindestens 650 mm beträgt. Den Metallbügel (B)