Installing your hob in complete safety
mini 5 cm
Kit d'isolation (SAV)
mini 4 mm
Above an oven
4 cm mini
Ensure that the unit crossbar does not block the air
passage, make a bevel if necessary.
Above a cupboard or drawer unit
Gap
MINI 4 mm
If the appliance underneath your hob produces excess heat :
this will be detected by a safety device incorporated into your induction hob. A high temperature will be indicated by a
series of dashes or F7 will appear in the display.
If this happens we suggest you either create an opening in the side of the unit and/or install an insulation kit available
from the After-Sales Dept (ref 75X1652), which will protect your hob from the heat generated beneath it.
Providing the advice on ventilation given above is followed, your hob can be installed above any piece of kitchen
equipment.
Always ensure that the air vents beneath the hob are kept clear.
Your induction hob must always be adequately ventilated.
Opening in the side of the
unit approx 8 cm x 5 cm
Insulation kit (after-sales service)
During long cooking sessions, leave the
drawer slightly open to promote the
circulation of warm air.